Nature of Business: Authorized Retail Dealer & Distributor, Additional Business: Wholesaler, Retailer, Service Provider: Supplier, Company CEO: Mohammed Azhruddin, Registered Address:#G2,4th Cross, 13th Main Road Jakkasandra, 1st Sector HSR Layout, 5th Sector, Karnataka ,Bangalore -560034 Total Number of Employees: 35 to 50 People, Year of Establishment: 2009, Legal Status of Firm: LLP, Annual Turnover: Rs. 20 - 30 Crore

GENSETS – 75 kVA / 82.5 kVA / 100 kVA / 125 kVA

125kVA

Features:

Its Recovery Time, Easily The Best In Its Category, Guarantees A Seamless Switchover To The Back-Up Power. Moreover, Its Effective Governing System Controls The Voltage Fluctuations, Thus Ensuing Complete Safety Of Your Equipment.

Its got one of the most preferred engines fitted inside – the Mahindra Powerol engine. Compact and low on vibration, this engine has the smallest footprint as compared to other engines of identical ratings. Making the DG set apt even for roof-mountings.

Each and every Powerol DG set complies with the most stringent noise and emission norms stipulated by the Central Pollution Control Board of India (CPCB).

It’s got other advantages too. Like, it’s transported through the Mahindra Transport Solutions Group. It is installed and commissioned through a Mahindra authorized dealer. It even comes with an annual maintenance contract. It is most fuel efficient in its class It offers zero-leak engines Manual and AMF control panel options are also available.

A Powerol DG set can be used in the Telecom, Defence and Railway sectors. It can also be installed at places like petrol pumps, hospitals, super markets, banks and construction sites.

Description

Silence is Golden: India’s most silent Genset brand

Mahindra Powerol’s ‘Spectro’ series of diesel gensets is one of the most silent gensets manufactured by the brand. It has sturdy wheels and a long handle which allows easy mobility of the genset.

Assurance

Power fluctuations can affect your business as well as day to day operations. Diesel gensets act as back up against power cuts providing you with uninterrupted power supply. Mahindra Powerol has a wide network of authorized dealers & skilled service engineers spread across India. Customers just need to dial our Toll-free number – 1-800-419-1999 & service will be available at the doorstep.

  • Over 400 sales and service touch points.
  • Easy Finance schemes available.
  • Fuel Efficient Engines.

Appliances that can run on 75kVA Gensets

Segments used for:

Bungalows, Small Offices, Small Shops

Technical Specifications

Parameters DG Models
Duty (Standby/ Prime) Prime
50 Hz Prime Rating(kVA) 75 kVA
Rated(kWe) 60
Engine Model 41035 GM-C2
No of Cylinders 4
Phase / Voltage (V) 3 / 415
Power Factor 0.8 (lagging)
Current (A) 104.4
Governing class G2
Starting system 12 V DC Elec
Fuel tank capacity 180
Genset Dimension (LxWxH $$) (mm) Approx. 3000 X 1150 X 2135
Genset Weight (kg) approx. 1350
Rated Speed RPM 50/1500
Engine Specification
Make / Series Mahindra
Power Output# (HP) 103
Aspiration Turbocharged Intercooled
Bore x Stroke (mm) 96 x 122
Displacement (Lit) 3532
Fuel consumption @ 75% load (lit/hr) ^ 13.5
Fuel consumption @ 100% load (lit/hr) ^ 17.8
Lube oil specification SAE15W40 CI4
Total lubrication system capacity (lit) 10
Lube Oil Consumtion (lit/hr) $ 0.1% of Fuel Consumption
Lube oil change period (hrs.) 300 hrs. for Oil Top Up
600 hrs. for Oil change
Radiator coolant capacity (liter) 19
Alternator
Make CG/LS
Enclosure Type IP23
Voltage regulation ±1%
Class of insulation Class H
Maximum Unbalanced Load across Phases 25%

All Specifications are at Standard NTP operating conditions
^ Considering 0.845 Specific Gravity of diesel, +5 % Tolerance
# Engine Power at 110 % load
Fuel -High Speed diesel (HSD IS 1460:2005)
* Represent the Standby Ratings
$ Considering 0.89 Specific Gravity of Oil
Engine Power will have ± 5 % Tolerance
** For CG only 3 Phase Configuration available
$$Height Without Silencer

Appliances that can run on 82.5kVA Gensets

Segments used for:

Bungalows, Small Offices, Small Shops

Technical Specifications

Parameters DG Models
Duty (Standby/ Prime) Prime
50 Hz Prime Rating(kVA) 82.5 kVA
Rated(kWe) 66
Engine Model 41125A GM-C2
No of Cylinders 4
Phase / Voltage (V) 3 / 415
Power Factor 0.8 (Lagging)
Current (A) 114.8
Governing Class G2
Starting System 12 V DC Elec
Fuel Tank Capacity 160
Genset Dimension (LxWxH $$) (mm) Approx. 2950 x 1075 x 1575
Genset Weight (Kg) Approx. 1500
Rated Speed RPM 50/1500
Engine Specification
Make / Series Mahindra
Power Output# (HP) 111.5
Aspiration Turbocharged Intercooled
Bore x Stroke (mm) 96 x 132
Displacement (Lit) 3882
Fuel Consumption @ 75% Load (Lit/Hr) ^ 13.5
Fuel Consumption @ 100% Load (Lit/Hr) ^ 18.1
Lube Oil Specification SAE15W40 CI4
Total Lubrication System Capacity (Lit) 13.5
Lube Oil Consumption (Lit/Hr) $ 0.1% of Fuel Consumption
Lube Oil Change Period (Hrs.) 300 Hrs. for Oil Top Up
600 Hrs. for Oil Change
Radiator Coolant Capacity (Liter) 19
Alternator
Make CG/LS
Enclosure Type IP23
Voltage Regulation ±1%
Class of Insulation Class H
Maximum Unbalanced Load Across Phases 25%

All Specifications are at Standard NTP operating conditions
^ Considering 0.845 Specific Gravity of diesel, +5 % Tolerance
# Engine Power at 110 % load
Fuel -High Speed diesel (HSD IS 1460:2005)
* Represent the Standby Ratings
$ Considering 0.89 Specific Gravity of Oil
Engine Power will have ± 5 % Tolerance
** For CG only 3 Phase Configuration available
$$Height Without Silencer

Appliances that can run on 100kVA Gensets

Segments used for:

Bungalows, Small Offices, Small Shops

Technical Specifications

Parameters DG Models
Duty (Standby/ Prime) Prime
50 Hz Prime Rating(kVA) 100 kVA
Rated(kWe) 80
Engine Model mPower41265G
No of Cylinders 4
Phase / Voltage (V) 3 / 415
Power Factor 0.8 (Lagging)
Current (A) 139
Governing Class G2
Starting System 12 V DC Elec
Fuel Tank Capacity 250
Genset Dimension (LxWxH $$) (mm) Approx. 3500 x 1230 x 1425
Genset Weight (Kg) Approx. 1650
Rated Speed RPM 50/1500
Engine Specification
Make / Series Mahindra Mpower
Power Output# (HP) 126
Aspiration Turbocharged Aftercooled
Bore x Stroke (mm) 105 x 137
Displacement (Lit) 4800
Fuel Consumption @ 75% Load (Lit/Hr) ^ 17.3
Fuel Consumption @ 100% Load (Lit/Hr) ^ 23.1
Lube Oil Specification SAE 15W40CI4+
Total Lubrication System Capacity (Lit) 13.5
Lube Oil Consumption (Lit/Hr) $ < 0.1% of Fuel Consumption
Lube Oil Change Period (Hrs.) 500
Radiator Coolant Capacity (Liter) 19
Alternator
Make CG/LS/Stamford/Equivalent
Enclosure Type IP23
Voltage Regulation ±1%
Class of Insulation Class H
Maximum Unbalanced Load Across Phases 25%

All Specifications are at Standard NTP operating conditions
^ Considering 0.845 Specific Gravity of diesel, +5 % Tolerance
# Engine Power at 110 % load
Fuel -High Speed diesel (HSD IS 1460:2005)
* Represent the Standby Ratings
$ Considering 0.89 Specific Gravity of Oil
Engine Power will have ± 5 % Tolerance
** For CG only 3 Phase Configuration available
$$Height Without Silencer

Appliances that can run on 125kVA Gensets

Segments used for:

Bungalows, Small Offices, Small Shops

Technical Specifications

Parameters DG Models
Duty (Standby/ Prime) Standby Prime
50 Hz Prime Rating(kVA) 125 kVA 125 kVA
Rated(kWe) 100 100
Engine Model mPower41565G mPower61565G
No of Cylinders 4 6
Phase / Voltage (V) 3 / 415 3 / 415
Power Factor 0.8 (Lagging) 0.8 (Lagging)
Current (A) 173.7 173.7
Governing Class G2 G2
Starting System 12 V DC Elec 24 V DC Elec
Fuel Tank Capacity 250 250
Genset Dimension (LxWxH $$) (mm) Approx. 3500 x 1230 x 1425 3500 x 1230 x 1425
Genset Weight (Kg) Approx. 1650 1855
Rated Speed RPM 50/1500 50/1500
Engine Specification
Make / Series Mahindra Mpower Mahindra Mpower
Power Output# (HP) 156 156
Aspiration Turbocharged Aftercooled Turbocharged Aftercooled
Bore x Stroke (mm) 105 x 137 105 x 137
Displacement (Lit) 4800 7200
Fuel Consumption @ 75% Load (Lit/Hr) ^ 21.4 21.4
Fuel Consumption @ 100% Load (Lit/Hr) ^ 28 28
Lube Oil Specification SAE 15W40CI4+ SAE 15W40CI4+
Total Lubrication System Capacity (Lit) 13.5 20.2
Lube Oil Consumption (Lit/Hr) $ < 0.1% of Fuel Consumption < 0.1% of Fuel Consumption
Lube Oil Change Period (Hrs.) 500 500
Radiator Coolant Capacity (Liter) 19 22.5
Alternator
Make CG/LS/Stamford/Equivalent CG/LS/Stamford/Equivalent
Enclosure Type IP23 IP23
Voltage Regulation ±1% ±1%
Class of Insulation Class H Class H
Maximum Unbalanced Load Across Phases 25% 25%

All Specifications are at Standard NTP operating conditions
^ Considering 0.845 Specific Gravity of diesel, +5 % Tolerance
# Engine Power at 110 % load
Fuel -High Speed diesel (HSD IS 1460:2005)
* Represent the Standby Ratings
$ Considering 0.89 Specific Gravity of Oil
Engine Power will have ± 5 % Tolerance
** For CG only 3 Phase Configuration available
$$Height Without Silencer

PRODUCT RANGES

285_315_gasgenset

GAS GENSETS - 285kVA / 315kVA

Gas Genset

GAS GENSETS - 10.5 kVA / 15 kVA / 20 kVA / 25 kVA / 100 kVA / 125 kVA

500kVA

GENSETS - 400 kVA / 500 kVA / 625 kVA

250kVA

GENSETS - 250kVA / 320kVA

125kVA

GENSETS - 160kVA / 180kVA / 200kVA

10kva-genset-img

GENSETS - 10 kVA / 15 kVA

Nature of Business

Authorized Retail Dealer & Distributor

Additional Business

Wholesaler
Retailer

Service Provider

Supplier

Company CEO

Mohammed Azharuddin

Registered Address

S. No. 12, Plot No. 4 - A/2/10, Nanded Phata, Near Savali Dhaba, Sinhagad Road, Chinhwad,, Pune- 411041, Maharashtra, India

Total Number of Employees

35 to 50 People

Year of Establishment

2009

Legal Status of Firm

LLP

Annual Turnover

₹20 - 30 Crore

Nature of Business

Authorized Retail Dealer & Distributor

Additional Business

Wholesaler
Retailer

Service Provider

Supplier

Company CEO

Mohammed Azharuddin

Registered Address

S. No. 12, Plot No. 4 - A/2/10, Nanded Phata, Near Savali Dhaba, Sinhagad Road, Chinhwad,, Pune- 411041, Maharashtra, India

Total Number of Employees

35 to 50 People

Year of Establishment

2009

Legal Status of Firm

LLP

Annual Turnover

₹20 - 30 Crore