Nature of Business: Authorized Retail Dealer & Distributor, Additional Business: Wholesaler, Retailer, Service Provider: Supplier, Company CEO: Mohammed Azhruddin, Registered Address:#G2,4th Cross, 13th Main Road Jakkasandra, 1st Sector HSR Layout, 5th Sector, Karnataka ,Bangalore -560034 Total Number of Employees: 35 to 50 People, Year of Establishment: 2009, Legal Status of Firm: LLP, Annual Turnover: Rs. 20 - 30 Crore

GENSETS – 10 kVA / 15 kVA

10kva-genset-img

Features:

Its Recovery Time, Easily The Best In Its Category, Guarantees A Seamless Switchover To The Back-Up Power. Moreover, Its Effective Governing System Controls The Voltage Fluctuations, Thus Ensuing Complete Safety Of Your Equipment.

Its got one of the most preferred engines fitted inside – the Mahindra Powerol engine. Compact and low on vibration, this engine has the smallest footprint as compared to other engines of identical ratings. Making the DG set apt even for roof-mountings.

Each and every Powerol DG set complies with the most stringent noise and emission norms stipulated by the Central Pollution Control Board of India (CPCB).

It’s got other advantages too. Like, it’s transported through the Mahindra Transport Solutions Group. It is installed and commissioned through a Mahindra authorized dealer. It even comes with an annual maintenance contract. It is most fuel efficient in its class It offers zero-leak engines Manual and AMF control panel options are also available.

A Powerol DG set can be used in the Telecom, Defence and Railway sectors. It can also be installed at places like petrol pumps, hospitals, super markets, banks and construction sites.

Description

Silence is Golden: India’s most silent Genset brand

Mahindra Powerol’s ‘Spectro’ series of diesel gensets is one of the most silent gensets manufactured by the brand. It has sturdy wheels and a long handle which allows easy mobility of the genset.

Assurance

Power fluctuations can affect your business as well as day to day operations. Diesel gensets act as back up against power cuts providing you with uninterrupted power supply. Mahindra Powerol has a wide network of authorized dealers & skilled service engineers spread across India. Customers just need to dial our Toll-free number – 1-800-419-1999 & service will be available at the doorstep.

  • Over 400 sales and service touch points.
  • Easy Finance schemes available.
  • Fuel Efficient Engines.

Appliances that can run on 10kVA Gensets

Segments used for:

Bungalows, Small Offices, Small Shops

Technical Specifications

Genset 10 kVA
Duty (Standby/ Prime) Prime
50 HZ PRIME Rating(kVA) 10 kVA
50 HZ PRIME Rated(kWe) 8
50 HZ PRIME Engine Model 2185GM-C2
No of Cylinders 2
No of Phases 1/3
Output Voltage (V) 230/415
Power Factor (lagging) 0.8
Current (A) (1Phase / 3Phase) 43.5/13.9
Frequency (Hz)/ RPM 50/1500
Governing class A1
Starting system 12 V DC electrical
Fuel tank capacity 55
Genset Dimension (LxWxH $$) (mm) Approx. 1700 X 900 X 1250
Genset Weight (Kg) Appx
Engine Specification
Make / Series Mahindra mPower
Power Output# (HP) 18
Aspiration Naturally Aspirated
Bore x Stroke (mm) 88.9 x 110
Displacement (Lit) 1366
Fuel consumption @ 75% load (lit/hr) ^ 2.4
Fuel consumption @ 100% load (lit/hr) ^ 2.9
Lube oil specification SAE15W40 CH4
Total lubrication system capacity (lit) 6
Lube Oil Consumtion (lit/hr) $ 0.15% of Fuel Consumption
Lube oil change period (hrs.) 300 hrs. for Oil Top Up
Radiator coolant capacity (liter) 5.5
Alternator
Make CG/LS
Enclosure Type IP23
Voltage regulation +/- 1%
Class of insulation Class H
Maximum Unbalanced Load across Phases 25%

All Specifications are at Standard NTP operating conditions
^ Considering 0.845 Specific Gravity of diesel, +5 % Tolerance
# Engine Power at 110 % load
Fuel -High Speed diesel (HSD IS 1460:2005)
* Represent the Standby Ratings
$ Considering 0.89 Specific Gravity of Oil
Engine Power will have ± 5 % Tolerance
** For CG only 3 Phase Configuration available
$$Height Without Silencer

Appliances that can run on 15kVA Gensets

Segments used for:

Bungalows, Small Offices, Small Shops

Technical Specifications

Parameters Stand By Prime
Duty (Standby/ Prime) Stand By Prime
50 Hz Prime Rating(kVA) 15 kVA 15 kVA
50 Hz Prime Rated(kWe) 12 12
50 Hz Prime Engine Model 2205 GM C2 3255 GM C2
No of Cylinders 2 3
No of Phases 1/3 1/3
Output Voltage (V) 230/415 230/415
Power Factor (lagging) 0.8 0.8
Current (A) (1Phase / 3Phase) 65.2/20.9 65.2/20.9
Frequency (Hz)/ RPM 50/1500 50/1500
Governing class A1 A1
Starting system 12 V DC Electrical 12 V DC Electrical
Fuel tank capacity 55 75
Genset Dimension (LxWxH $$) (mm) Approx. 1700 X 900 X 1250 1875 X 900 X 1287
Genset Weight (Kg), Appx 673 738
Engine Specification
Make / Series Mahindra Mpower Mahindra Mpower
Power Output# (HP) 20 25
Aspiration Naturally Aspirated Naturally Aspirated
Bore x Stroke (mm) 88.9 X 120 88.9 X 110
Displacement (Lit) 1490 2048
Fuel consumption @ 75% load (lit/hr) ^ 2.7 3
Fuel consumption @ 100% load (lit/hr) ^ 3.6 3.8
Lube oil specification SAE15W40 CH4 SAE15W40 CH4
Total lubrication system capacity (lit) 6 6.5
Lube Oil Consumtion (lit/hr) $ 0.15% of Fuel Consumption 0.15% of Fuel Consumption
Lube oil change period (hrs.) 300 Hrs. For Oil Top Up
600 Hrs. For Oil Change
300 Hrs. For Oil Top Up
600 Hrs. For Oil Change
Radiator coolant capacity (Liter) 5.5 5.5
Alternator
Make CG/LS CG/LS
Enclosure Type IP23 IP23
Voltage Regulation +/- 1% +/- 1%
Class Of Insulation Class H Class H
Maximum Unbalanced Load Across Phases 25% 25%

All Specifications are at Standard NTP operating conditions
^ Considering 0.845 Specific Gravity of diesel, +5 % Tolerance
# Engine Power at 110 % load
Fuel -High Speed diesel (HSD IS 1460:2005)
* Represent the Standby Ratings
$ Considering 0.89 Specific Gravity of Oil
Engine Power will have ± 5 % Tolerance
** For CG only 3 Phase Configuration available
$$Height Without Silencer

PRODUCT RANGES

285_315_gasgenset

GAS GENSETS - 285kVA / 315kVA

Gas Genset

GAS GENSETS - 10.5 kVA / 15 kVA / 20 kVA / 25 kVA / 100 kVA / 125 kVA

500kVA

GENSETS - 400 kVA / 500 kVA / 625 kVA

250kVA

GENSETS - 250kVA / 320kVA

125kVA

GENSETS - 160kVA / 180kVA / 200kVA

125kVA

GENSETS - 75 kVA / 82.5 kVA / 100 kVA / 125 kVA

Nature of Business

Authorized Retail Dealer & Distributor

Additional Business

Wholesaler
Retailer

Service Provider

Supplier

Company CEO

Mohammed Azharuddin

Registered Address

S. No. 12, Plot No. 4 - A/2/10, Nanded Phata, Near Savali Dhaba, Sinhagad Road, Chinhwad,, Pune- 411041, Maharashtra, India

Total Number of Employees

35 to 50 People

Year of Establishment

2009

Legal Status of Firm

LLP

Annual Turnover

₹20 - 30 Crore

Nature of Business

Authorized Retail Dealer & Distributor

Additional Business

Wholesaler
Retailer

Service Provider

Supplier

Company CEO

Mohammed Azharuddin

Registered Address

S. No. 12, Plot No. 4 - A/2/10, Nanded Phata, Near Savali Dhaba, Sinhagad Road, Chinhwad,, Pune- 411041, Maharashtra, India

Total Number of Employees

35 to 50 People

Year of Establishment

2009

Legal Status of Firm

LLP

Annual Turnover

₹20 - 30 Crore